Fuse - changing 2

Fuse - changing 1

CIRCUIT PROTECTION - Basic circuits

Circuit type Fuse - amps MCB - amps
Fixed lighting 5 6
Radial (up to 20 sq m floor area ) 20 20
Radial (up to 50 sq m floor area ) 30 32
Ring 30 32

With the main switch still off, remove the fuse from its carrier and look to see whether it is of the replaceable wire type or cartridge type.

Cartridge or rewireable fuse

It is always as well to keep a selection of cartridge fuses or fuse wire of the appropriate ratings near the consumer unit so that they may easily be found when required.

With any fuse, it is essential that the replacement is of the correct rating. Do not simply rely on replacing it with the same type as was already there. It may not be correct. Use the table to determine which rating is required

cartridge fuse carrierThe cartridge type have fuses which look similar to those you would find in a standard household plug.

The fuse is removed by pulling it out from between the sprung metal clips. The new one is simply inserted back into the clips.

Rewireable fuse carrierThe rewireable type have a fuse wire held at both ends by a small retaining screw.

Undo both ends and remove the broken wire. Make a ‘U’ shape in the end of the replacement wire and wind it clockwise around one of the retaining screws. Re-fasten the screw. Take the other end of the wire and feed it through to the other screw following the same route that the old wire took. Wind the end clockwise around the screw and fasten it.

Rewireable fuse carrierFinally, trim off any excess wire so that stray ends will not cause problems.

Insert the fuse back in its carrier on the consumer unit..

Circuit breakers or MCB

With MCBs, simply look to see which one has ‘tripped’ and having remedied the fault which triggered it, reset the button.

Once you are sure that the fault has been rectified, replace the cover of the consumer unit and switch back on. Check that the circuit is now functioning correctly.

If the fuse blows again straight away, the fault has not been rectified and must be dealt with. If you are not sure what the problem is, seek professional help.

Share This Page.


NEED A
RECOMMENDED
TRADESMAN ?

Diyfixit has teamed up with Rated People to bring you thousands of
RECOMMENDED
TRADESMEN
accross the UK

FIND ONE NOW

Comment on this Article.
Please use the Login at the top of the page to comment.-OR-Login With Facebook

Electrics Safety

AlertThis material is " for information purposes " only. Strict rules govern what electrical work can be done without notification and inspection.
Read more ...

Rapid Toolbox
Cookie Policy

Avoiding the Pain !

Top 10 Tips for
Employing a Tradesman

Your Must-Know Guide to avoid being ripped off by Rogue Traders

Builder's Blog Latest ...

And join in with the
Diyfixit Forums